10 Results for the search " IEEE":
Author: n.sene
Type: Publication
Date: 2015-04-01
DISPERSED ENERGY RESOURCES SCHEDULING FOR THE INTENTIONAL ISLANDING OPERATION OF DISTRIBUTION SYSTEMS
Description:
The paper presents an algorithm for the automatic optimal scheduling of dispersed energy resources (DERs) and of under-load tap changers (ULTCs) position. The aim of the scheduling problem consists in... see more the minimization of the voltage deviations with respect the rated value, of the DERs production deviation with respect the maximum efficiency point, and of the network losses.
The system incorporates also a procedure to facilitate the intentional islanding maneuver of the distribution network. The adopted approach is based on iterative solution of linear-constrained multi-objective optimization problems. The nonlinear power flow relationships are linearized by means of the calculation of sensitivity coefficients to small variations of the control variables (namely, controllable DERs power outputs and ULTCs positions). The algorithm is implemented in Matlab environment to exploit different solvers and suitably interfaced with EMTP-RV for three-phase power flow detailed calculations. In particular, two optimization solvers are adopted: the least square method and the goal attainment approach. The relevant results are compared using the IEEE 34-node distribution feeder as test case.
Authors: A. Borghetti, C.A. Nucci, M. Paolone, M. Bosetti
Tag(s): Dispersed generation, active distribution networks, islanding operation.
Author: n.sene
Type: Publication
Date: 2015-04-01
On the Mitigation Effect of Surge Arresters on the Lightning Performance of Overhead Distribution Lines
Description:
For the accurate statistical assessment of the lightning performance of distribution lines one needs to
take into account the presence of protection devices such as surge arresters and shielding ... see morewire/neutral
groundings. Indeed, the presence of those devices can significantly modify the indirect lightning
response of the overhead line and, therefore, the relevant lightning performance.
In particular, this paper aims at investigating the impact of the presence of surge arresters on the
indirect lightning performance of overhead distribution lines having realistic configuration.
Specifically, reference is made to typical Italian distribution lines. The investigation is performed with
the help of a statistical procedure developed by the authors – based on the Monte Carlo method and of
the use of an accurate modelling/calculation tool for the induced surges – that has been recently
compared with one proposed in the IEEE 1410 Std for the same purpose, and shown to be more
complete and suitable for the problem of interest. The paper also aims at investigating the influence of
the presence of surge arresters on the indirect lightning surges transferred through power transformers.
Such an additional investigation is performed by means of a suitable high-frequency power
transformer mode integrated with the lightning-induced computation tool.
Authors: A. Borghetti, F. Napolitano, C.A. Nucci and M. Paolone - University of Bologna, Italy
CIGRE – Colloquium Cavtat - Application of Line Surge Arresters in Power Distribution and Transmission Systems
Tag(s): Lightning statistics, induced overvoltages, lightning performance of distribution lines, surge arresters, shielding wires groundings, Monte Carlo method.
Author: n.sene
Type: Publication
Date: 2015-04-01
Continuous-Wavelet Transform for Fault Location in Distribution Power Networks: Definition of Mother Wavelets Inferred From Fault Originated Transients
Description:
The paper presents a fault location procedure for distribution networks based on the wavelet analysis of the fault-generated traveling waves. In particular, the proposed procedure implements the conti... see morenuous wavelet analysis applied to the voltage waveforms recorded during the fault in correspondence of a network bus. In order to improve the wavelet analysis, an algorithm is proposed to build specific mother wavelets inferred from the fault-originated transient waveforms. The performance of the proposed algorithm are analyzed for the case of the IEEE 34-bus test distribution network and compared with those achieved by using the more traditional Morlet mother wavelet.
Authors: Alberto Borghetti, Senior Member, IEEE, Mauro Bosetti, Mauro Di Silvestro, Carlo Alberto Nucci, Fellow, IEEE, and Mario Paolone, Member, IEEE
IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 23, NO. 2, MAY 2008
Tag(s): Continuous wavelet transform, distribution network, EMTP simulations, fault location, mother wavelet, power quality.
Author: gerinlajoie.luc
Type: Model
Downloaded: 431 times
Date: 2012-11-23
Extra control of machines - IEEE AVR
Description:
The proposed AVR sub-circuit models consist of a few IEEE 421 standard exciter[1] and Power Systems Stabilizer and governor. Don't forget to click the require observed signals in the SM devi... see morece, see Observe and Mechanical Tabs (vd, vq, if, Pmss, Efss, Omega_1, etc.) In this file, many duos and trios combinations of:
Exciter:
- IEEEX1 (dc1),
- IEEEX2,
- IEEEX4,
- IEEET5,
- EXST1,
- EXST1A,
Stabilizer:
- PSS1A,
- PSS2B,
- PSS4B,
- Q type II (var control)
Governor:
- IEEEG0,
- IEEEG1,
- IEEEG3,
- DEGOV1
- GAST,
- TGOV1,
- TGOV5[1]
IEEE Std 421.5, Recommended Practice for Excitation System Models For Power System Stability Studies, 2005
Tag(s): Components
Author: AdminEMTP-RV
Type: Document
Downloaded: 285 times
Date: 2012-06-18
Induction machine modeling for distribution system analysis using initialization and time-domain methods
Description:
Panel session paper to be presented at the IEEE T&D show in New Orleans (Oct. 2005)
Authors: J. Mahseredjian, S. Dennetière, B. Khodabakhchian and A. Xémard
Abstract:
This pap... see moreer is presented as part of an effort by the Distribution System Analysis Subcommittee to establish reference cases for induction machine modeling in distribution system analysis and unbalanced three-phase systems. This panel paper presents analysis results obtained when applying a full time-domain method with load-flow and steady-state initialization. The selected software is EMTP-RV. Problem solution complexities are discussed.